Flange size and rating chart

Outside diameter, bolt circle and bolting for the flange sizes most used on immersion and pipeline heaters. Tell us the standard and class of your nozzle and we match it.

ASME B16.5 Class 150

NPSOutside dia.Bolt circleBolts
½" 88.9 mm3.50 in 60.5 mm2.38 in 4 × ½"
¾" 98.6 mm3.88 in 69.8 mm2.75 in 4 × ½"
1" 107.9 mm4.25 in 79.2 mm3.12 in 4 × ½"
1¼" 117.3 mm4.62 in 88.9 mm3.50 in 4 × ½"
1½" 127.0 mm5.00 in 98.6 mm3.88 in 4 × ½"
2" 152.4 mm6.00 in 120.6 mm4.75 in 4 × ⅝"
2½" 177.8 mm7.00 in 139.7 mm5.50 in 4 × ⅝"
3" 190.5 mm7.50 in 152.4 mm6.00 in 4 × ⅝"
4" 228.6 mm9.00 in 190.5 mm7.50 in 8 × ⅝"
5" 254.0 mm10.00 in 215.9 mm8.50 in 8 × ¾"
6" 279.4 mm11.00 in 241.3 mm9.50 in 8 × ¾"
8" 342.9 mm13.50 in 298.4 mm11.75 in 8 × ¾"
10" 406.4 mm16.00 in 361.9 mm14.25 in 12 × ⅞"
12" 482.6 mm19.00 in 431.8 mm17.00 in 12 × ⅞"

EN 1092-1 PN16

DNOutside dia.Bolt circleBolts
DN 15 95 mm 65 mm 4 × M12
DN 20 105 mm 75 mm 4 × M12
DN 25 115 mm 85 mm 4 × M12
DN 32 140 mm 100 mm 4 × M16
DN 40 150 mm 110 mm 4 × M16
DN 50 165 mm 125 mm 4 × M16
DN 65 185 mm 145 mm 8 × M16
DN 80 200 mm 160 mm 8 × M16
DN 100 220 mm 180 mm 8 × M16
DN 125 250 mm 210 mm 8 × M16
DN 150 285 mm 240 mm 8 × M20
DN 200 340 mm 295 mm 12 × M20
DN 250 405 mm 355 mm 12 × M24
DN 300 460 mm 410 mm 12 × M24

Class 150 pressure–temperature rating

Carbon steel, ASME B16.5 material group 1.1. The allowable pressure falls as the design temperature rises; a hot oil or steam duty can need Class 300 even at modest pressure.

Temperature (°C)Max. working pressure (bar g)
−29 to 3819.6
10017.7
15015.8
20013.8
25012.1
30010.2
3508.4
4006.5

How it is worked out

Values are taken from ASME B16.5 and EN 1092-1. Raised-face height, flange thickness and hub dimensions depend on the flange type (weld neck, slip-on, blind) and are confirmed on the general-arrangement drawing.

JIS B2220 and other standards are built to order; state the standard, class and face type in your inquiry.

Other selection tools

  • Heater sizing calculator Required kW for continuous flow or batch heat-up of water, thermal oil or air.
  • Watt density guide Design ranges by medium, and why oil needs a larger heater than water for the same kW.
  • Electric vs gas operating cost Annual energy cost of the same heat duty from an electric heater and a gas-fired heater.
  • Thermal oil properties Density, specific heat and conductivity of a typical mineral heat transfer oil by temperature.
  • Unit converter Power, temperature, pressure, flow and watt density units used on heater datasheets.

For a quotation, include your process medium, operating temperatures and supply voltage.

Get a quote
Get a quote Email