Thermal oil properties

Typical mineral heat transfer oil, 0 to 320 °C. Use it for a first sizing; the datasheet of the oil you fill is what the final design uses.

Temperature (°C) Density (kg/m³) Specific heat (kJ/kg·K) Conductivity (W/m·K) Volume vs 20 °C fill
0 877 1.81 0.136 -1.4 %
20 864 1.88 0.134 +0.0 %
40 852 1.96 0.133 +1.5 %
60 839 2.03 0.131 +3.0 %
80 827 2.11 0.130 +4.6 %
100 814 2.18 0.128 +6.2 %
120 801 2.26 0.126 +7.9 %
140 789 2.33 0.125 +9.6 %
160 776 2.41 0.123 +11.4 %
180 764 2.48 0.122 +13.2 %
200 751 2.56 0.120 +15.1 %
220 738 2.63 0.118 +17.1 %
240 726 2.71 0.117 +19.1 %
260 713 2.78 0.115 +21.2 %
280 701 2.85 0.114 +23.4 %
300 688 2.93 0.112 +25.6 %
320 675 3.00 0.110 +28.0 %

How it is worked out

ρ = 877 − 0.63 × T cp = 1.81 + 0.00373 × T λ = 0.136 − 0.00008 × T

Linear fits to published data for ISO VG 32 class mineral heat transfer oils, T in °C. Maximum bulk and film temperatures are specific to each oil; the heater's watt density is chosen to keep the film below its limit.

Other selection tools

For a quotation, include your process medium, operating temperatures and supply voltage.

Get a quote
Get a quote Email